Troubleshooting guide
| ITEM | PROBLEM | PROBABLE REASONS | CORRECTIVE ACTIONS |
|---|---|---|---|
| One Piece Closet | |||
| 1. Water not coming in bowl area while flushing | Water line not cleaned properly | Before installtion clean the incoming as well as out going line | |
| Malfunctioning of mechanism inside tank | Change the mechanism | ||
| No water in flush tank | Raise the height change slot to the max level | ||
| 2. Leaking of water in bowl area | Push button is locked | Release the push button | |
| Fitment of mechanism end part and outlet of tank not fitted properly | After opening the mechanism check the fittment | ||
| Malfunctioning of mechanism inside tank | Change the mechanism | ||
| 3. Insufficient water quantity for effective flushing | Height change slot adjusted at lower level | Closet is not levelled properly | |
| 4. Uneven flow of water from both side of closet | Raise the height change slot to the max level | Level the closet properly | |
| Wall Hung Closet | |||
| 1. Water not coming in bowl area while flushing | Flush valve/concealed cistern is not working | Change the flush valve / concealed cistern | |
| Flush pipe is not inserted up the end of inlet hole | Insert the flush pipe upto the end of inlet | ||
| 2. Leaking of water in bowl area | Closet is not levelled | Level the closet properly | |
| 3. Insufficient water quantity for effective flushing | Connection between closet outlet and drainage pipe is improper | Engage experienced plumber for proper connection | |
| Wash Basin Top | |||
| 1. Overflow chocked and foul smell | Full threaded waste coupling might be in use | Replace it by slot cut coupling | |
| 2. Water logging in platfrom and bowl area | Bracket and basin fixing may be the reason | Levelling to be checked and rectified | |
| 3. No tap hole in the basin | Tap hole is semi punched from back side | Call plumber and open up the semi punched hole | |
| EWC/Pan/Anglo Indian | 1. Water not coming in bowl area while flushing | Flush bend is not inserted up to the end of inlet hole | Insert the flush pipe upto the end of inlet |
| Levelling issue | To be levelled properly |